INSTRUCTIONS:

Check out the new MoBeam posts! To find K40 conversion information use the "INDEX", "SEARCH" or "LABELS" sections in the sidebar.
Showing posts with label K40 DC Power. Show all posts
Showing posts with label K40 DC Power. Show all posts

Monday, June 27, 2016

K40-S DC Power Systems Design


Background

This post outlines the design for DC power in the K40-S

The  K40-S BUILD INDEX with schematics

Donate:

Please consider donating (button to the right of this post).

Your donations help fund additional research, tools and parts that I will return to the community as information and how-to's. 

General K40 DCPS design configurations


The LPS capacity:

  • +24VDC @1amp
  • +5VDC @ 1amp
Internally these are created from separate sections of the LPS so they have a total capacity of 29VA.
I do not know the power requirements for K40+smoothie when under full dynamic load and therefore
I am skeptical that 24VDC@1 amp can run everything in this box at full power.

I have not measured the dynamic load so at this point it is a suspicion. Power budgeting & verification is on my list of to-do's.

What configuration to use?

How you wire the DC power depends on what your expected full load will be.
Your full load includes DC current drawn from any/all of these:

  • Smoothie
  • Local Control panel (GLCD)
  • Steppers
  • Z table
  • Finder LED
  • DC pumps


DC Power Budget

Coming soon

Typical configurations


You can configure DC power to the Smoothie in three basic ways:

Way #1

+24VDC from the LPS
+5VDC from regulator installed on-board smoothie
Capacity: 24VA
Pro's: simple two wire connection
Potential Con's: marginal power for anything else, local display, finder led, Z table, pump etc.

Way #2 

+24VDC from LPS
+5V from LPS
Capacity: 29VA
Pro's: more capacity 5VDC + 12VDC
Potential Con's: marginal power for anything else, local display, finder led, Z table, pump etc.

Way #3

+24VDC from external supply with selected capacity
+5VDC from regulator installed on-board smoothie
Capacity: based on external supply choice
Pro's: full DC capacity for K40 + expansion. Simple 2 wire DC wiring
Potential Con's: more complex wiring of AC mains (to add on supplies) and purchase cost of external supplies.

What works?


Many of the K40 conversions use Way#1 and 2, so it seems to work, I just do not know if it is marginal.

I chose Way#3 because:
  1.  I want as much isolation as possible from the HV laser supply. In my configuration only the grounds are common.
  2. I wanted to make sure that the motors had full capacity under dynamic loads. I do not know the actual loads so I took the safe route :).
  3. I wanted extra capacity for future accessories like the local GLCD and driving the stepper for the lift table. 
BTW: I currently use the LPS 24VDC & 5VDC  for other accessories such as external lift table and the finder LED.

You can employ Way#1 or 2 and then measure the PS voltage to insure that it is not drooping.

My Current Design

SCHEMATIC

The design is incomplete and is being documented here:

24VDC:

Separate 24vdc supply to smoothie to run the board and motors.
https://www.amazon.com/gp/product/B018TG7I4W/ref=oh_aui_detailpage_o02_s00?ie=UTF8&psc=1
or:
https://www.amazon.com/gp/product/B00UHI3NGS/ref=ox_sc_act_title_2?ie=UTF8&psc=1&smid=AWUSKMLB3J3ZT

5VDC Power:

Integrated 5VDC regulator on smoothie and Display adapter provides all 5VDC.

http://shop.uberclock.com/collections/smoothie/products/switching-regulator-dc-to-dc-5v

Laser Power Output:

12VDC:

Separate 12VDC supply: pump, cabinet lights, temperature alarm.
https://www.amazon.com/gp/product/B00UHI3NGS/ref=ox_sc_act_title_2?ie=UTF8&psc=1&smid=AWUSKMLB3J3ZT

Fuses:

All DC supplies will be fused using: